MIL-S-63302(AR)
4.5.8 MDF assembly tests - Dwg. 9328723.
4.5.8.1 Output test of MDF assembly.  The samples selected
shall be temperature conditioned, half at minus 60 -5F and
half at 160 +5F for two (2) hours min.  The assembly shall
be subjected to the output test as specified in 3.3 within five
minutes after removal from the conditioning chamber.  Observation
shall be made for compliance with requirements of 3.3.  Witness
plate, 5/8 X 1 1/4 X 1 1/4 inches, shall be 2024-T351 aluminum
alloy bar (rolled drawn or cold finished) Federal Specification
QQ-A-225/6 having a Brinell Hardness of 120-130, HB 10/500/30.
No confinement of MDF Assembly shall be used. (Destructive test.)
4.5.8.2 Pull test of MDF assembly.  The assembly shall be
placed in an approved fixture and the pull load applied as
specified on the applicable drawing.  Observations shall be made
for compliance with the requirements of the drawing.  Assemblies
subjected to this test shall not be returned to the lot.
(Destructive test)
4.5.9 Separation test of slider assembly - Dwg.
9329822-1,-2.  The slider assembly shall be placed in an approved
fixture and the separation load applied as specified on the
applicable drawing.  Observations shall be made for compliance
with the requirements of the drawing.  Assemblies subjected to
this test shall not be returned to the lot.
(Destructive test)
4.5.10 Flexibility test of MDF, PBXN-5, lead sheathed - Dwg.
9328726.  This test shall be performed in accordance with
MIL-C-50697.  Observation shall be made for compliance with the
requirements of the Drawing-Note 3.  Samples subjected to this
test shall not be returned to the lot but shall be used in 4.5.12.
4.5.11 Neutron radiog raphic examination.
4.5.11.1 MDF, PBXN-5 lead sheathed. Dwg. 9328726.  The MDF
cord shall be subjected to neutron radiographic examination.
Observation shall be made for the requirements of the drawing -
Notes 4 and 5. (Non-destructive inspection)
4.5.11.2 MDF assembly. Dwg. 9328723.  The MDF assembly shall
be subjected to neutron radiographic examination.  Observation
shall be made for compliance with the requirements of the
drawing. (Non-destructive inspection)