Click here to make tpub.com your Home Page

Page Title: Seven-foot drop
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-S-63523A(AR)
3.6.3 Seven-foot drop.  The simulators, when packaged shall not
fire when subjected to drops from a height of seven feet as
specified in 4.5.8.6.  After being subjected to such drops (and
additional testing as indicated for First Article Tests) , the
devices shall show no signs of damage, shall be safe to handle and
fire, and shall meet the performance requirements when test fired as
specified in para. 4.5.8.6.
3.6.4 Loose carqo transport.  The simulators, when packaged
shall not fire when subjected to loose cargo transport as specified
in 4.5.8.8.  After being subjected to the loose cargo transport (and
additional testing as indicated for First Article Tests, or Quality
Conformance Inspection), the devices shall show no signs of damage,
shall be safe to handle and fire, and shall meet the performance
requirements when test fired as specified in para. 4.5.8.8.
3.6.5 Five-foot drop.  The unpackaged simulators shall not fire
when dropped from a height of five feet as specified in 4.5.8.5.
After being subjected to such a drop (and additional testing as
indicated for First Article Tests or Quality Conformance
Inspection), the devices shall be safe to handle and fire, and shall
meet the performance requirements when test fired.
3.6.6 Forty-foot drop.  The simulators, when packaged shall not
fire when dropped from a height of forty feet as specified in
4.5.8.7 and shall be safe to handle and dispose of.
3.6.7 Low temperature.  The simulators shall be capable of
withstanding low temperature conditions as specified in 4.5-8.2 and
shall meet the performance requirements when test fired.
3.6.8 Hiqh temperature.  The simulators shall be capable of
withstanding high temperature conditions as specified in 4.5.8.3 and
shall meet the performance requirements when test fired.
3.6.9 Leakaqe test.  The simulators, when packaged shall be
capable of withstanding exposure to the leakage test as specified in
4.5.6.  Leakage shall constitute a failure.
3.6.10 Leak test.  The Simulator shall not leak when tested as
specified in 4.5.7.  Leakage shall constitute a failure.
3.6.11 Jumble.  The simulator shall comply with the following
requirements when tested as specified in 4.5.5.
6

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business