MIL-S-82529 (OS)
STANDARDS
FEDERAL
Preservation, Packaging, and Packing
FED-STD-102
Levels
MILITARY
Sampling Procedures and Tables for
MIL-STD-105D
Inspection by Attributes
Marking for Shipment and Storage
MI L-STD-129"
Mechanical Vibrations of Shipboard
MIL-STD-167
Equipment
DRAWINGS
Bureau of Naval Weapons
Switch, Thermal Mark 56 Mod l, and
LD 540562
all documents listed thereon
(Copies of specifications, standards, drawings, and publications requested
by contractors in connection with specific procurement functions should be ob-
tained from the procuring activity or as directed by the contracting officer. )
3.  REQUIREMENTS
3.1 General requirements. Unless otherwise specified in the contract or
order, all materials and treatments of materials and parts used in the manu-
facture of the switch shall be in accordance with the requirements specified
herein and with the applicable documents listed in BuWeps LD 540562.
3.2 Preproduction samples. Unless otherwise specified in the contract or
order, preproduction samples of the switch shall be manufactured using the meth-
ods and procedures proposed for production. The sample shall be tested as
specified in Section 4 herein and is for the purpose of determining that prior to
starting production, the contractor's production methods are capable of yielding
items that comply with the technical requirements of the contract.
3.3 Performance and product characteristics. The switch shall meet the
following performance and product characteristics.
3.3.1 Insulation resistance. After being conditioned at a temperature of
75 plus or minus 5 degrees Fahrenheit (F) and a relative humidity of 75 plus or
minus 5 percent for a period of not less than twenty-four hours, the insulation
resistance shall not be less than 100 megohms. When the insulation resistance
is measured during or subsequent to the environmental tests specified in
2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business