Figure 1. Dimensions and configuration - Continued
Up
Switches, Sensitive, SPDT, Momentary, Double Break, 10 Amperes, Unsealed
Next
Table I. Electrical ratings



MIL-S-8805/29B
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Enclosure design: 1 (unsealed).
Temperature characteristic: 1 (-55 to +85C).
Shock type: M (100 g).
Vibration grade: 10 to 55 Hz, method 201, MIL-STD-202.
Weight: 1.50 ounce maximum.
Operating characteristics:
Actuating force: 16 to 26 ounces.
Pretravel: .030 inch maximum.
Movement differential: .004 inch maximum.
Overtravel: .005 inch minimum.
Strength of actuating means: 25 pounds.
Terminal strength: 30 pounds
Contact resistance: Not applicable.
Mechanical endurance: 50,000 cycles.
Electrical endurance: 25,000 cycles.
Electrical ratings: See table I.
Group B inspection: Not applicable.