MIL-T-18232B(AS)
FINISH. - Metal propellers shall be finished in accordance
3.10.13.3
with Specification MIL-F-7179 and wood propellers in accord-
ance with Specification MIL-P-26366 as applicable. Propeller tips shall be
painted glossy orange yellow conforming to color number 13538 of Federal Standard
No. 595 with enamel conforming to Specification MIL-E-7729 at a distance of
approximately two inches inboard from the tips.
3.10.13.4
PROPELLER CLEARANCE. - Propeller clearance shall take into
consideration deflections of engine-mount vibration isolators
and supporting structures to the extent which would result from accelerations
consistent with the condition assumed.
3.10.13.4.l
RADIAL CLEARANCE. - Radial clearance between tips of pro-
pellers and the catapult or launching airplane structure,
shall be not less than two inches. Surfaces near propeller tips shall be stiffened
against vibration, ice from the propeller, and subsequent failure. Ample
clearance shall be provided in a direction parallel to the axis of the propeller
to allow for blades deflection under load.
3.11
INSTRUMENTS
3.11.1
INSTRUMENTS. - The installation of instruments that are re-
quired for normal operation of the target shall be as required
by the detail specification. Instruments used for flight test purposes shall be
approved by NAVAIR.
3.12
HYDRAULIC AND PNEUMATIC SYSTEMS
3.12.1
HYDRAULIC SYSTEM* - Hydraulic systems shall be provided in
accordance with Specification MIL-H-25475.
3.12.1.1
DESCRIPTION. - The type and class of system shall be as
required by the detail specification.
3.12.1.2
SUMMARY OF ACTUATED ITEMS. - Items operated hydraulically
shall be as required by the detail specification.
3.12.1.3
HYDRAULIC FLUID WEIGHT0 - For design purposes, the weight of
Specification MIL-O-5606 hydraulic fluid shall be calculated
at 7 pounds per gallon.
3.12.1.4
FINISH OF DETAIL PARTS. - Finishes of detail parts shall be
provided in accordance with Specification MIL-H-8775.
3.12.2
PNEUMATIC SYSTEM. - Pneumatic systems shall be provided in
accordance with Specification MIL-P-5518.
3.12.1
DESCRIPTION. - The type and class of system shall be as
required by the detail specification.
40