(a) Ambient temperature test.  This test shall be canducts. at the
temperature of 21.1C
from the heights stipulated in Table I, drop
Then drop on
in succession on corners 5-1-2, 6-3-4, 5-2-3, and 6-1-4.
Suitable test rigging is described
face 3 and face 5 (see Figure 1).
in Method 216 of Federal Test Method Standard No. 101.
(b) High temp erature test.  This test shall be conducted in accordance
From the
with the requirements of MIL-STD-810, Method 501, Procedure I.
height stipulated in Table I, drop in succession on comers 5-1-2, 6-3-4,
Suitable
5-2-3, and 6-1-4.  Then drop on face 3 and face 5 (see Figure 1).
test rigging is described in Method 216 of Federal Test Method Standard
No. 101.
(c) Low temp erature test.  This test shall be conducted In accordance
with the requirements of MIL-STD-810, Method 502.  From the height stipulated
in Table I, drop in succession on comers 5-1-2, 6-3-4, 5-2-3, and 6-1-4.
Suitable test rigging is
Then drop on face 3 and face 5 (see Figure 1).
described in Method 216 of Federal Test Method Standard No. 101.
4.5.11  Leak test.  The hot water technique shall be conducted in accord-
ance with Method 5009 of Federal Test Method Standard No. 101.
PREPARATION FOR DELIVERY
5.
5.1  Presentation and packaging.  The levels of preservation and packag-
ing shall be as specified (see 6.2).
5.1.1
Level A
The test set shall be packaged in accordance with
5.1.1.1 Unit packaging.
Method IID of MIL-P-116.  The unit package shall contain one test set.
Not applicable.
5.1.1.2
Intermediate package.
Not applicable.
5.1.2
Level B.
5.1.3
Level C
The test set shall be packaged in accordance with
5.1.3.1  Unit packaging.
Method III of MIL-P-116.  The unit package shall contain one test set.
Not applicable.
5.1.3.2
Intermediate package.
Packing shall be Level A or Level C, as specified (see 6.2).
5.2 Packing.
The number of unit packages per pack,
5.2.1  Number of packages per pack.
for Level C, shall be as specified in the contract or order.