4.5.3 Test equipment.- In conjunction with 4.5.2.2 the following
standard test equipment shall be utilized in the performance of the
applicable tests as specified in 4.6 and 4.7.
DESCRIPTION
NOMENCLATURE
Standard type conforming to the
1.
Hot and cold chamber
accuracies outlined in test facili-
ties specified under test facilities
of MIL-F-13926.
Standard shop type conforming to the
2.
Insulation resistance checker
accuracies outlined in 4.5.2.2
Power supply
0 to 100 VDC output within 10%
3.
accuracy
Standard shop type accurate to with-
4.
Torque wrench, scales and
Adapters
in 10% of specification requirements
Pressure gage
5.
Standard shop type accurate to within 10%
of specification requirement
4.6 Test methods and procedures.
4.6.1 Environmental.
4.6.1.1 Temperature test.-  The telescope shall be subjected to
test procedure I of MIL-F-13926; however, the temperatures specifed in
3.3.1 and 3.3.2 shall apply. When the telescope has been stabilized at
the temperature specified, the result of the specified test shall con-
form to the limits outlined in 3.3.1 and 3.3.2 using test procedures out-
lined herein.
4.7 Performance testing.
4.7.1 Orientation.-  Proper orientation is assured when the telescope
is properly mounted and secured to a testing device, the accuracy of
which shall be equal to or exceed the accuracy depicted in Drawing F8599924,
and when aligned as outlined in set-up instructions outlined on Drawing
F8599924. When the telescope is aligned as outlined above, set the me-
chanical cant index line, and observe that the level vial position is as
specified in 3.6.During acceptance inspection, energize the telescope's
electrical system and observe that the illumination of the level vial
when energized with the voltage specified is in conformance with 3.8.1.
With the voltages specified in 3.8.2, observe that the reticle markings
are in conformance with 3.8.2 and also observe that a rotation of the
rheostat will cause illumination to increase from low to bright. Prior
to performing acceptance inspection, remove image tilt by unlocking the
eyepiece portion of the telescope and rotating the eyepiece until the
longest reticle line is positioned parallel to the comparable collimator
target line. Lock in this position.