MIL-T-46626C(OS)
The radiographic plate identification shall include item nomenclature, the complete lot number, the span of
serial numbers displayed, and the contract number. The radiographs of the entire production lot shall
accompany the ballistic sample to the activity conducting the production lot acceptance test. Defective
thrusters found during X-ray review are to be marked on the X-ray prior to shipment and those defective items
shall be removed from the production lot. Film interpretation of the radiographs shall verify the presence and
correct positioning of the following parts:
a.
Setscrew, commercial, 0.125-inch diameter, 44UNF-3A x 1/8-inch-long
b.
O-ring, P/N MS28775-012
c.
O-ring, P/N MS28775-212
d.
O-ring, P/N MS28775-214
e.
Keys (4), P/N 8593857
f.
Trunnion, P/N 8593860
g.
Sleeve, end, P/N 8593869
h.
Spring, piston locking, P/N 8593871
i.
Pin, shear, P/N 8593876
j.
Pin, firing, P/N 8593878
k.
Ring, snap, P/N 8593879
l.
Ring, holding, P/N 8593880
m.
Piston and plug assembly, P/N 8593881
n.
Head, P/N 8593882
o.
Body and pellet assembly, P/N 8593884
p.
Screw, cap, socket head, P/N 8593885
q.
Washer, P/N MS35338-136
r.
Setscrew (2), P/N MS51964-27
s.
Cartridge, impulse, M43, P/N 8593275
4.3.4 Functional.
4.3.4.1 Ballistics. The test sample shall be rigidly supported so that the entire thrust is borne by the
thruster mounting points. The samples shall be tested within 10 minutes after removal from the temperature
conditioning chamber. When this time limit is exceeded, the sample units shall be reconditioned at the
original temperatures.
4.3.4.2 Temperature conditioning. Each assembled thruster shall be conditioned for not less than 4
hours nor greater than 24 hours. When reconditioning thrusters at 65F, all condensation shall be removed
from the exterior surfaces before returning the thruster to the conditioning chamber.
4.3.4.3 Final lock test. The test shall be performed in accordance with 3.7.2.1. The thruster fired under
load condition shall be separated from the testing set-up in its "as-fired" condition and installed in a
compression testing device to determine compliance with the requirements.
4.4 Inspection of packaging. The sampling and inspection of the packaging, packing, and container
marking shall be in accordance with section 5.