None defined
Minor
201 Contents loose Manual/Visual
202 Carton broken or damageVisual
d
203 Number of units incorrect Visual
204 Marking missing, incorrect, or illegible
Visual
205 Tape incomplete
Visual
4.5.3 Inspection testing. The following tests shall be performed in accordance with 4.6.
4.5.3.1 Hardness. Fifty units from each heat treated lot of components shall be tested for
compliance with the requirements on the applicable drawing. Failure of any unit to comply with
the drawing requirements shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each body and head shall be subjected to the hydrostatic
pressure test. Failure of any cap or chamber subassembly to comply with 3.4 shall be cause for
rejection of the subassembly.
4.5.3.3 Structural strength. Each thruster shall be subjected to the structural strength
test. Failure of any thruster to comply with the requirements of 3.6 shall be cause for rejection
of the thruster.
4.5.3.4 Shear pin strength. Fifty pins from each lot of shear pins shall be tested for shear
strength. Failure of any shear pin to comply with 3.7 shall be cause for rejection of the lot.
4.5.3.5 Breakaway torque. Each body and holding ring shall be subjected to a breakaway
torque. Failure of any unit to comply with the requirements of 3.5.2 shall be cause for rejection
of the unit.
4.5.3.6  Protective finish. The number of units for protective finish tests shall be in
accordance with the applicable specification. Failure of any unit in the inspection sample to
comply with the requirements of the applicable specification shall be cause for rejection of the
lot.
4.5.3.7 Residual magnetism. Each assembly shall be subjected to the test for excessive
residual magnetism as specified in 4.6.7. Failure of any unit in the inspection sample to comply
with 3.10 shall be cause for rejection of the assembly.
4.6 Test methods and procedures.
4.6.1 Hardness. Prior to the application of protective finish, a hardness tester shall be
used to determine compliance with the requirements of the applicable drawing.
4.6.2 Hydrostatic pressure. Prior to application of protective finish the body and head shall
be mounted in the device, using a fixture for properly sealing all openings, and subjected to the
internal hydrostatic pressure to determine compliance with 3.4.