Click here to make tpub.com your Home Page

Page Title: Requirements
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-48134A (MU)
MILITARY
- Sampling Procedures and Tables for in-
MIL-STD-105
spection by Attributes (ABC-STD-105)
MIL-STD-109  - Quality Assurance Terms and Definitions
MIL-sTD-129  - Marking for Shipment and Storage
MIL-STD-1168 - Lot Numbering of Ammunition
MIL-STD-1169 - Packaging, Packing and Marking for
Shipment of Inert Ammunition Components
MIL-STD-1235 - Single and Multilevel Continuous
Sampling Procedures and Tables for
Inspection by Attributes
DRAWINGS
U. S. ARMY MUNITIONS COMMAND
9221789 - Procedure for Measuring Power Output of
M51 Test Set
9227694 - Test Set, Blasting Cap, M51 Assembly
(Copies of specifications, standards and drawings required by sup-
pliers in connection with specific procurement functions should be
obtained from the procuring activity or as directed by the Contract-
ing Officer.)
REQUIREMENTS
3.
3.1 Material. - Materials and parts shall be in accordance
with appl icable drawings and specifications.
3.2 Electrical Test Sets. - The electrical test sets shall
comply with all requirements specified on Drawing (dwg.) 9227694
and with all requirements specified in applicable specifications.
3.3 Embrittlement of Springs. - Cap springs, actuator springs
and armature springs shall not break when extended to the minimum
(min.) point of permanent distortion.
3.4 Air Leaks. - Test sets shall show no evidence of cracking
or separation of the parts or failure of the seals, and shall func-
tion satisfactorily.