4.3.3.5 Hardness of Cap (see dwg. 8800941) - Major Defect -
Code No.  27001.  - Twenty (20) caps shall be selected from each
If any cap fails to comply with the ap-
treated batch for test.
plicable  requirement, the heat treated batch represented by the
The test shall be performed as speci-
sample shall be rejected.
fied in 4.4.5 using equipment in accordance with 4.3.4.
(Destruc-
tive)
4.3.3.6 Hardness of Housing (see dwg. 8800936) - Major
Defect - Code No. 28001.  - Twenty (20) housings shall be selected
If any housing fails to comply
from each treated batch for test.
with the applicable requirement, the heat treated batch repre-
The test shall be per-
sented by the sample shall be rejected.
formed as specified  in 4.4.6 using equipment in accordance with
(Destructive)
4.3.4.
4.3.3.7
Drop Test (see 3.7) - Major Defect - Code No. 29001.-
A sample of 20 test sets shall be selected from each lot for this
The lot shall be rejected if one or more test sets fail to
test.
meet the specified requirement when tested as specified in 4.4.7,
This test shall be considered non-destructive provided the air
leak test for the items is passed subsequent to the drop test.
4.3.4  Inspection  Equipment. - The inspection equipment
required to perform the examinations and tests prescribed in this
section is identified under the "Method of Inspection" headings
in. 4.3.2 and 4.3.5 (see 6.3).
4,3.5 Dimensional Control of Plastic Parts. - In place of
the normal sampling and inspections associated with the Classifi-
cation of Defects, and after a curing time for the parts has been
approved (see 4.3.5.1),  a sample of three (3) parts (as molded)
from each cavity shall be fully inspected dimensionally to qualify
The molded parts
a new or reworked cavity for use in production.
As a control
shall carry the individual cavity identification.
of each cavity during production, the above quantity of parts
from each cavity shall be inspected for at least the defects
listed in Paragraphs 4.3.5.2 through 4.3.5.5 after continuous
production of each 5,000 parts or at the end of each week, which-
One (1) sample of the three (3) samples shall
ever occurs first,
If any defective parts are found dur-
be the last part produced.
ing qualification of the cavity,  the cavity producing the defec-
If any defective parts
tive part will not be used in production.
are found when inspection is performed for the control of the
cavity, the cavity producing the defective part shall be removed
Further,  that portion of production since the
from production.
20