MIL-T-48236 (MU)
MIL-STD-1235 -
Single and Multilevel Continuous
Sampling Procedures and Tables
for Inspection by Attributes
DRAWINGS
U.S. ARMY MUNITIONS COMMAND
9272546 - Test Set, Electrical Circuit, M40E1
(Copies of specifications, standards and drawings required by
suppliers in connection with specific procurement functions
should be obtained from the procuring activity or as directed
by the contracting officer).
REQUIREMENTS
3.
3.1 Material.-Materials, parts and assemblies shall be
in accordance with applicable drawings and specifications.
3.2 Test sets.-The test sets shall comply with all require-
ments specified on drawing 9272546 and with all requirements
specified in applicable specifications.
3.3 Five foot drop.-Test sets shall show no evidence
of cracking or separating after being subjected to the five
foot drop test and shall function satisfactorily.
3.4 Wiring.-The distance between any portion of the
bulb circuit and any portion of the resistor circuit shall
be not less than 1/8 inch.
3.5 Functioning of Test Set.- The test set shall function
satisfactorily as evidenced by a flash of the lamp with the
output terminals connected to a dummy load, and by no flash of
the lamp with the output terminals open.
3.6 Functioning of lamp.-The lamp (see dwg. 9275725) shall
function satisfactorily and shall not blow out when connected
in series with a fifteen (15) ohm resistor.