MIL-T-48466B(AR)
Where any one assembly fails to meet any
4.5.3.2  Acceptance.
Rejected lots
specified requirement, the lot shall be rejected.
shall be resubmit-ted for reinspection only after all assemblies
are re-examined or retested and all defective assemblies are
removed or defects corrected.
4.6 Methods of inspection.
4.6.1
Performance
tests.
4.6.1.1 Cable test set indicators/switches.
4.6.1.1.1  Power  switch/indicator.  Activate the power
switch and observe the power indicator to verify that the lamp
illuminates.
Activate the power
4.6.1.1.2  Continuity switch/indicator.
Observe the
switch and press and release the continuity switch.
continuity indicator to verify that the indicator lamp
illuminates when the continuity switch is depressed and is
extinguished when the continuity switch is released.
4.6.1.1.3 Cable test switches.
4.6.1.1.3.1  Short-circuit  detection.  Activate the power
switch and each cable test switch in successive position (S1
through S83).
Observe the continuity indicator to verify that the
indicator lamp remains off.
4.6.1.1.3.2  Open-circuit  detection.  Activate the power
switch, place panel switches S1 through S83 in the normal
position, and successively connect pins 1 through 83 of connector
Observe that the continuity lamp does not
15J1 to 24V dc return.
Place panel switches S1 through S83 in the test position
light.
successively (pins 1 through 83 of 15J1 still connected to 24V dc
return) and observe the continuity indicator to verify that the
indicator lamp illuminates.
4.6.1.1.4 Interlock test switch indicator.  Activate the
power switch and place a jumper between pins 84 and 85 of
Observe the interlock test switch indicator to
connector 15J1.
Press the interlock
verify that the indicator lamp illuminates.
test switch and observe that the indicator lamp will extinguish.
4.6.1.1.5  Input power .
Perform the performance tests of
All
4.6.1.1.1 through 4.6.1.1.4 at 18V dc and at 30V dc.
requirements shall be satisfied at both conditions.
4.6.1.2  Insulation  resistance.  Measure the insulation
resistance between pins of connector 15J1 and case in accordance
Verify that the
with MIL-STD-202, Method 302, Test Condition B.
resistance is not less than 10 megohms.
11