Page Title: Band 2 and 3 Equation
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-48621A (AR)
BAND 2 AND 3 EQUATION:
For use with base band spectrum
analyzer (item 30) and frequency selective voltmeter [item 29) where
FN . = FC and  reference sideboard  level = .36 DBO
DBCN = DBVN - DBVC - 10 log BW - 36 +
2.
where:
DBCN = Level of noise below the carrier at Fc.
DBVN = Level of noise at FC below 1 volt.
DBVC = Level of calibration signal below 1 volt.
Bw
= Bandwidth of measuring device in Hz.
DBF = Filter attenuation characteristic ( in DB ) at FC.
ff.
Using the data computed for column 6 of each Data
Table, calculate the measured Integrated noise power
(in DB below the carrier) for each band-under-test
(DBCX ) using the following formula:
where :
DBCI = Integrated Noise Power (in DB) relative to the carrier
in the measured band.
DBCNi = Level of tge Noise (in DB) in a 1 Hertz bandwidth
relattve to the carrier at frequency FNi
= Frequency away from the carrier where the noise was
FN
measured.
1 + 1 = Next frequency above FNi where the noise was measured.
s
= Total number of measured frequencies.
= (DBCNi - DBCNi+l) / .(10 log FN
`i
1+1)
FN