| MIL-T-60694B
204
Cut, damaged, or improperly sealed bag
Visual
4.3.2.23 Box, Packing, Ammunition, Drawing 8858440.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Visual/Manual
202
Strapping missing, loose, broken, or improperly assembled
Visual/Manual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.3.2.24 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9217560.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Hardware missing, loose, broken, or improperly engaged
Visual
203
Strapping missing, loosed, broken, or improperly engaged
Visual
204
Contents of box exposed
Visual
205
Box damaged
Visual
206
Marking missing, incorrect, or illegible
Visual
4.4 Inspection testing. The following tests shall be performed in accordance with 4.5.
4.4.1 Hydrostatic pressure. Each body shall be subjected to the hydrostatic pressure test. Failure of any
body to comply with 3.2 shall be cause for rejection of the unit.
4.4.2 Breakaway torque. Each body and ring nut subassembly shall be subjected to a breakaway torque
application. Failure to comply with the requirements of column C, table II shall be cause for rejection of the
subassembly.