MIL-T-63443(AR)
4.6.3  Cleanliness.  The optical surfaces of the Telescope
shall be inspected for cleanliness in accordance with
-
MIL-0-13830.  The Telescope reticle shall not contain particles
Area
of dirt in excess of the amount specified in 3.4.1.
inspection of dirt particles shall be accomplished by means of a
Scratch and Dig Standard conforming to Drawing C7641866 for a
comparison of the area of the dirt particles with the dig size
of the standard.
The Telescope shall conform to its respective
cleanliness requirement.  This test shall be performed subsequent
to vibration.
Sealing tests for the Telescope shall be
4.6.4  Sealinq.
performed utilizing special testing equipment conforming to the
Two Station-Pressure Tester, Drawing F8565556, wherein a special
hose adapter to pressurize the Telescope will be required.  The
procedure for the internal pressure test described in the set-up
and operating instructions on Sheet 1 of Drawing F8565556 shall
The Telescope shall be pressurized with a dry nitrogen
apply.
gas to the required pressure and maintained for the time
specified.
Leakage shall not be evident within the time period
specified for sealing.
4.6.5  Resolution.  To perform this test, a wall target
containing the appropriate resolution target shall be employed.
Construction of the resolution target and the method of
inspection shall  outlined in MIL-O-13830.  The telescope must
resolve the test pattern within the limits outlined in 3.4.3.
During this test, the telescope may be supported in a "V"
block.
The use of packing or shims may be used to position the
telescope.
When making this test, use a dioptometer having a
minimum of 4 power.
4.6.6  Eyepiece Focus.  The eyepiece focus test shall be
Performed with the aid of a dioptometer conforming to the Diopto-
The dioptometer shall be adjusted by
meter, Drawing F7680631.
setting the slide scale index to zero, and the eyepiece of the
dioptometer shall be adjusted for the best focus on the diopto-
meter reticle.  Place the dioptometer at the eyepiece of the
Telescope on the special testing equipment.  Adjust the diopto-
meter,  by movement of the dioptometer tube, until the Telescope
reticle appears in sharp focus.  The diopter scale on the tube
of the dioptometer shall indicate between the -0.75 (3/4) and
-1.0 diopter to conform with 3.4.4.