MIL-T-63536(AR)
output
Input
Voltage at Pin J1-D
apply 1.5 V rms
a. At V signal in-
shall be equal to the
180 degrees out of
put Pin J1-j with
input at Pin J1-V
phase with the 26
return at Pin J2-g
Vac input at Pin J2-U 7%.
(28 Vdc return) and
apply 0.5 V rms,
at Evaluation
400 Hz
error signal
input Pin J1-V
with return to
Pin J1-W
Output
Input
At the point where
Voltage at Pin J1-D
b.
Vary the input
output becomes as
shall be 0.0 30
at Pin J1-j
millivolts.
specified, the input
(with return to
Pin J2-g) and
at J1-j shall be 0.820
10% V rms in phase
with 0.5 V rms
400 Hz (1800 out
Vith the 26 Vac input
at Pin J2-U
of phase with 26
Vac input at J2-U)
at Pin J1-V (with
return to Pin J1-11)
3.6.1.4.3 One and one-half degree azimuth error detector. With the
initial conditions as specified below, the outputs shall be in accordance with
3.6.1.4.3.1 and 3.6.1.4.3.2.
a. Input power as specified in 3.1.3
b. +18 Vdc 10 percent at Pin J2-D
c. -18 Vdc 10 Percent at Pin J2-E
d. 7(+0, -1 V) rms, 400 HZ (5 percent) at Pin J1-A, in phase with
the 26 Vac applied to Pin J2-U, with return to Pin J1-B
e. 28 (+0.5, -O) Vdc through a 10,000 ohm (5 percent) 0.25 watt
resistor to Pin J2-b