MIL-T-81527B(AS)
3.4.1.6.2.7.8 Controls.
The Blower Assembly shall be activated from
the Test and Control Rack by Meither placing the RSC FUNCTION switch to
STBY or OPR or by depressing the AIR COOL pushbutton switch.
3.4.1. 6.2.7.9 Connections.
The electrical connector shall be
MS31OOA18-11P,
3.4.1.6.2.8 Remote Safetv Unit,
3.4.1.6.2.8.1 Function.
The Remote Safety Unit shall provide the means
for an emergency cut-off of power to the system and shall be installed on the
front edge of the overhead structure of the Rear Frame to the right of the
top support of the Pallet Shaft Assembly.
It shall be accessible to operat -
ing positions at the pallet bench, the Radio Frequency Noise Analyzer and
the RF Section Support Assembly.
3.4.1.6.2.8.2 Form Factor.
This unit shall not exceed 5-1/2 inches by
4 inches by 2 inches.
The weight of the unit shall not exceed 2 pounds.
3.4.1.6.2.8.3 Controls.
The Remote Safety Unit shall provide a red
momentary pushbutton switch.
When depressed, the switch shall operate in
conjunction with the Power Control Panel to remove all power from the
Radar Set.
When the control has been operated, power can be reapplied
only by operation of the Power On Switch (PWR ON).
3,4. 1. 6.2.8.4 Indication.
The unit shall have a red warning indication
light which shall be continuously lit whenever transmitter high voltage is
The warning light shall start flash -
present in the AN/APG-59 Radar Set.
ing any time conditions are such as to permit RF radiation from the antenna,
3. 4.1.6.2.9 Test Point Bracket.
3.4.1.6.2.9.1 Function.
A test point bracket with test points capable of
continous monitoring, and associated with the transmitter, shall be provided
to back up BIT and FIM comparators.
3.4.1.6.2.9.2 Form Factor. The dimensions of the test point bracket shall
not exceed 6 inches by 6.5 inches by 2. 7 inches, and it shall be contained
within the nominal dimensions of the Bench Assembly. The weight of the
bracket shall not exceed 1 pound.
18