MIL-T-81527B(AS)
3.4.1.6.4 Indicator Bench.
3.4.1.6.4.1 Function,
The Indicator Bench shall mount and furnish an
operating environment for the AN/APG-59 Radar Set Command indicator,
Radar Indicator, and Indicator Control, and provide 115 -Vat, Convenience
Power Outlets, conforming to MIL-C-3767.
.
3.4.1.6.4.2 Form Factor.  The Indicator Bench shall not exceed 64 inches
by 28- 1/8 inches by 75 inches and the weight shall not exceed 550 pounds.
The Indicator Bench shall consist of the following items:
(a) Mechanical Support Structure.
(b) Radar Indicator Support Structure.
(c) Command Indicator Support Structure.
(d) Indicator Control Support Structure.
(e) Test Set Support Structure.
3.4.1.6.4.2.1 Mechanical Support Structure.
The Mechanical Support Structure shall be
3.4.1.6.4.2.1. 1 Function.
capable of being bolted to the deck. It shall mount the items specified in
(see section 3.4.1.6.4.2(b), (c) and (d)) and shall provide work and storage
space.
The Mechanical Support Structure shall
3.4.1.6.4.2.1.2 Form Factor.
provide a bench top a nominal 64 inches by 26 inches, 31 -7/8 inches above
Storage space shall be provided beneath the bench top in the
deck level.
form of drawers and cabinet space. A vertical storage drawer shall be in-
stalled at the center of the Mechanical Support Structure below the bench
top to store cables used with the Table-Rack.  The Radar Indicator Support
Structure shall be installed on the right side of the bench top, The Command
Indicator Support Structure shall be installed on the left side of the bench
top .
The top rear of the Mechanical Support Structure shall form a shelf
64 inches by 15 inches whose upper surface shall be 75 inches above the
Provisions shall. be made to suspend the Indicator
surface of the deck,
Control Unit of the AN/APG-59 Radar Set below the top shelf at the right
side of the Mechanical Support Structure and the Test Set Support Structure
below the top shelf at the left side of the Mechanical Support Structure.