LFTS.  Regulation from no load to full load, and for normal values of facility
line voltage variations shall not exceed 2 percent.  Ripple voltage for direct
current [de) power forms shall not exceed 150 millivolts (mV) peak-to-peak ,
(P-P).  The power forms listed in Table II shall be provided.
3.2.1.12 Interface.
The LFTS shall provide the Interfaces specified in
the following,
3.2.1.12.1 Liquid cooler interface.  The LFTS shall interface with Cooler,
Liquid, Electronic Equipment HD-957( )/AWM-23(V) through coolant lines which
enter the LFTS at the top of bay no. 1.
3.2.1.12.2 Clean air interface.  The LFTS shall interface with the clean
air through ducts which enter the LFTS at the top rear of each test console.
3.2.1.12.3 Electrical Power interface.  The LFTS shall interface with
electrical power for the convenience outlets at one end of the convenience
outlet strip mounted on the top of the front face of the LFTS.  The LFTS
shall interface with all other electrical power through power lines entering
the top of bay number 1.
3.2.2 Utilities.
Applicable.
3.2.2.1 Electrical power.  Applicable.  Electrical power required for
operation of the LFTS shall be as listed in Table III.
TABLE II
SECONDARY POWER FORMS, REGULATED
-6-