Click here to make tpub.com your Home Page

Page Title: Built in test (BIT) functions
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-81785C(AS)
(3)
Frequency modulated ranging (FMR) linearity.  Measure
frequency variation from the ideal FMR slope character-
istics, in the frequency region about the ideal frequency,
50 Hz.
to an accuracy of
AIM-54 missile rear link command. - Measure frequency to
(4)
1 kHz in the X-band region.
an accuracy of
AIM-7F pulse doppler modulation. Measure:
(5)
(a) Modulation frequency to an accuracy of
0.5 Hz.
5 percent for
(b) Modulation index to an accuracy of
indices between O and 30.0.
Frequency modulation (FM) and amplitude modulation (AM)
(6)
noise.  Measure-
(a) FM noise to an accuracy of
2 dB in the range of
40 to 80 dB below the carrier.
(b) AM noise to an accuracy of
3 dB in the range of
100 to 140 dB below the carrier.
Reference oscillator output
c.
(1) Frequency.  Measure the reference oscillator frequency
10 Hz in the IF region.
to an accuracy of
(2) Voltage.  Measure voltage output to an accuracy of
0.05 V, root mean square (rms) in the region of 1.0 V.
d.
Built in test (BIT) functions
(1)
BIT FMR Ramp.  Measure ramp width to an accuracy of
30 microseconds(v sec.) in the region of 8 milliseconds
(ms) .
BIT reference.  Compare TO/LO offset against BIT reference
(2)
10 Hz in the IF region.
to an accuracy of
Phase lock bandwidth.  Verify bandwidth to an accuracy of
(3)
10 Hz over a range in the region of 4 megahertz (MHz).
Verify BIT X-band switch isolation in excess of 30 dB and
(4)
measure BIT target power in the region of -SO dBm, both
2.0 dB for the following:
to an accuracy of
(a) BIT RCVR TGT
(b) BIT RADOME HORN TGT
(c) MOAT TGT
Verify BIT power monitors.  Measure BIT TO and continuous
(5)
wave illuminator (CWI) monitor levels to an accuracy of
1.0V in the region of 10.5V.
e.
Pulse compression.  Measure incremental frequency of inverted
spectrum to an accuracy of
10 Hz over a range in the region of
3 MHz.
CWI driver.
-10-

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business