MIL-T-81785C(AS)
3.6.3.2 Panel, Test, Electrical C-9177( )/AWM-23(V).  The electrical
test panel shall provide the controls, displays and switching capability to
conduct functional and fault isolation tests on the WRAs assigned to the RFTS.
Controls on the front panel shall be provided to command WRA Power On or
Power Off, command emergency off for station power, select and enable function-
al or fault isolation tests, select and apply input signals to WRAs, select
measurement instruments during test, command SSI Word Generator to provide
desired word, control setting of attenuators, and control level of simulated
NRA inputs.  Displays on the front panel shall be provided to display test
number, test mode and status, and SSI BIT fault.
3.6.3.3 Panel, access.  The access panel shall provide cover for bay
structure mounted electrical wiring.
The signal comparator
3.6.3.4 Comparator, Signal CM-434( )/AW-23(V).
shall provide:
a.
The capability to determine modulation frequencies and
modulation indices associated with the AIM-7E and AIM-7F
Missiles.
b.
Timing and gating functions necessary for operation and test
of the receiver-transmitter group WRAs.
c.
The capability to measure the slope and linearity of the FMR
ramp modulated X-band output of the Oscillator, Radio Fre-
quency 0-1633( )/AWG-9 under test.
3.6.3.5 Dummy Load, Electrical DA-630( )/AWM-23(V),  The dummy load shall
provide the capability to test the high power outputs of the transmitter
power supplies by means of operating into a liquid cooled load assembly. Re-
sistive load elements and associated high voltage switching relays shall be
enclosed within the liquid filled assembly.
3.6.3.6 Transducer, TR-283( )/AWM-23(V). The transducer shall provide
the capability to provide fault and monitoring signals for detection of
inadequate cooling by means of coolant flow transducers.
3.6.4 Console, Test, Radio Frequency OJ-250( )/AWM-23(V).
The equipment
of this console shall be as specified below.
The power dis-
3.6.4.1 Panel, Power Distribution SB-3694( )/AWM-23(V).
tribution panel shall provide the capability to:
Control RFTS power function.
Indicate that input power forms are applied to the test
station.
Provide overload protection for the RFTS.
c.
d.
Display RFTS malfunction indication.
3.6.4.2 Signal generator.
The signal generator, RF Communications Incor-
porated RF-808-863-008, or equivalent, shall provide IF signals.