MIL-T-82570A(OS)
4.4.1.2 Temperature.  Room ambient 65 degrees Fahrenheit (F) to 95
degrees F (18
degrees centigrade (C) to 35 degrees C).
Normal ground atmospheric pressure.
4.4.1.3 Altitude.
4.4.1.4 Vibration:
None.
4.4.1.5 Humidity:
Room ambient to 95 percent relative maximum.
4.4.2 Test results.  When specified in the contract or order (See 6.2),
test results shall be recorded, or verification noted, as required, opposite
corresponding paragraph numbers on the Quality Conformance Inspection Data
Sheet Appendix) for each torpedo tube assembly inspected (See 5.4).
4.4.3 Acceptance criteria.  Failure of Torpedo Tube Mk 32 Mod 5 or Mk 32
Mod 7 to pass any examination or test of this section shall be cause for
rejection.
4.4.4 Test and inspection equipment and facilities. The manufacturer
shall furnish and maintain all necessary test equipment and facilities and
shall provide personnel for performing all quality conformance tests. The
test equipment shall be adequate in quantity and, when definite requirements
are not specified, shall be of sufficient accuracy and quality to permit
performance of the required quality conformance tests. To perform the tests,
the following items of test equipment, or equivalent", are required:
4.4.4.1 A means for producing a hydrostatic pressure of 4500 psig.
4.4.4.2 A water pressure gage capable of reading 4500 psig with an
accuracy of plus or minus 1/4 percent.
4.4.4.3 A 0-3000 psig high pressure air source.
4.4.4.4 An air line filter, to remove water, oil, and dirt, which shall
not pass particles larger than 50 microns.
4.4.4.5 An air pressure gage of O to at least 3000 psig with an accuracy
of plus or minus 1./4 percent at 2500 psig.
4.4.4.6 A "GO" gage for the barrel in accordance with NAVSEA Dwg 2320787.
4.4.4.7 Standard high potential test equipment capable of an output of
1000 volts, 60 to 100 Hz.
4.4.4.8 Megohm bridge, 500 volts dc, with a range of 0.1 to 1,000,000
megohms.
12

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business