Click here to make tpub.com your Home Page

Page Title: Electrical Requirements
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
c.
Special Purpose Cable Assembly CX11069/U for Testing Power Supplies
used in Red Dog Launchers.
Special Purpose Cable Assembly CX11070/U for Testing AERO-3B Launcher
d.
and all Power Supplies used in AERO-3B and Type IX and Type IXA Pylons.
e.
Special Purpose Cable Assembly CX11071/U for Testing Type IX and Type
IXA Pylons.
Special Purpose Cable Assembly CX12938/U for Testing F-5 Launcher
f.
power Supply, Type PP4506/A and PP4507/A.
Special Purpose Cable Assembly CX12937/U for Testing F-5 Launchers,
g.
Types LAU-57/A and LAU-58/A.
h.
Special Purpose Cable Assembly CX12939/U for Testing LAU-7A/A-1.
The equipment covered by this specification
3.3.4 Electrical Requirements.
shall facilitate the testing of all AIM-9 launcher power supplies by
simulating simultaneously the armament selector, switching and power
application of fire control circuits of each aircraft that utilizes the
AIM-9 Missile.  Test Set must also be capable of operating on any input
voltage combinations of 24 to 32 Volts Direct Current (VDC) and 102 to 120
Volts Root Mean Square (VRMS) at 320 to 522 cycles Alternating Current (AC).
Chassis and control panel of the SM-419/A Simulator shall be wired Per Drawing
7032760 in accordance with MIL-W-16878 while the special purpose cables shall
be wired per Drawing 7032758.
3.3.5 Reliability.
3.3.5.1 The equipment shall have Mean-Time-Between-Failure (MTBF) of 500
Failure is defined as the inability of the Test Set
hours at 90% confidence.
to meet all of the specified functional or mechanical requirements.
The Test Set shall be capable of operating for a total
3.3.5.2 Service Life.
of 7500 complete cycles with minor repairs/replacement of parts.
The case shall be a combination case as specified in
3.3.6 Case.
MIL-T-21200.
Part
Nameplate shall conform to MIL-N-18307.
3.3.7 Nameplate.
identifications shall conform to Drawings 7032758 and AF64D22408 and
MIL-M-13231.
3.4 Service Environments.
The Test Set shall operate without degradation of
performance under any combination of service conditions specified under Table
I of MIL-STD-810 for general base sheltered equipment.
The Test Set including all parts and accessories therein,
3.5 Workmanship.