MIL-V-18318B
5.2.1
Level A - Unless otherwise specified, sixty valves, packed
as specified in 5.1,1, shall be packed in overseas type exterior containers conforming
to PPP-B-591, PPP-B-636, or PPP-B-640, weather resistant Class. Closure and
strapping of the containers shall be in accordance with the applicable container
specification or appendix thereto. The gross weight of the packed shipping container
shall not exceed the weight limitations of the applicable container specification.
5.2.2
Level B - Sixty valves, packaged as specified in 5.1.1, shall
be packed in domestic type exterior containers conforming to PPP-B-591, PPP-B-636,
or PPP-B-640, Domestic Class. Closure and strapping of the containers shall be in
accordance with the applicable container specification or appendix thereto. The gross
weight of the packed shipping container shall not exceed the weight of the packed
shipping container shall not exceed the weight limitations of the applicable container
specification.
5.2.3
Level C - The packaged valves, which the carrier requires to
be packed, shall be packed within exterior type shipping containers in a manner that
shall insure safe transportation at the lowest rate to the point of delivery. The shipment
shall conform to the minimum requirements of the rules and regulations applicable
to the mode of transportation selected.
5.3
M a r k i n g - Nomenclature tags shall be inserted in each bag
showing title, part number or other data as required by procuring activity. In addition,
interior and exterior containers shall be marked in accordance with MIL-STD-129.
5.3.1
Precautionary marking - The following precautionary marking
shall appear on each package:
" CAUTION: DO NOT ALLOW CONTAMINANTS OF ANY
TO BE USED ON OR ABOUT THE OXYGEN
6.
NOTES
6.1
Intended use - The oxygen pressure regulating valve covered
by this specification is intended for use in aircraft oxygen systems for reducing the
high pressure (1800 psi) from oxygen cylinders to the lower working pressure of
oxygen-dispensing equipment.