MIL-W-63468A (AR)
4.4 Quality
conformance
inspection.
4.4.1
Inspection lot formation.
Inspection lots shall comply
with the lot formation provisions of MIL-A-48078.
In addition,
inspection lots of M261 Warheads shall contain:
a.
Grenades from no more than two lots bearing the same
inter fix number from one manufacturer .
M439 Fuzes bearing the same metal parts lot interfix
b.
number from one metal parts manufacturer.
c.
Expulsion charges from lots bearing the same lot
inter fix number from one manufacturer.
d.
Metal parts from no more than two lots bearing the
same interfix number from one manufacturer.
The quantity of warheads in each production lot shall not exceed
4,000.
4.4.2 Examination.
See MIL-A-48078.
Unless otherwise specified in the
a.
Sampling Plans.
Classification of Defects and Test tables, sampling
plans for major and minor defects shall be in
accordance with MIL-STD-105, Inspection Level II.