| MIL-A-21165A
TABLE I
SAMPLE SIZE, ACCEPTANCE CRITERIA, TESTS, AND EXAMINATIONS
OF THE ADAPTERs
TYPE OF
INSPECTION
ACCEPTANCE
INSPEC-
CRITERIA
TION
I
Visual examina-
--
Criti-
Every
Reject all units with
tion (see
cal
adapter
any critical defects.
classification
Minor
An acceptable quality
of' defects)
level of 4.0 defects
per hundred units for
minor defects.
Strength tests 1
Criti-
3.4.1
4.5.2
Inspec-
Acceptance number
1) Static hori-
cal
4. 5. 2.1
tion
zero rejection
zontal loading
Level S-1
number 1.
for each
2) Static ver-
4.5.2.2 strength
tical loading
test 2/
3) Impact
4.5.2.3
loading
Vibration and
Criti-
3.4.2
4. 5. 3
Inspec-
Acceptance number
Endurance 1/
cal
3. 4. 3
4.5.4
tion
zero rejection
Level S-1
number 1.
2/
`reparation for
Minor
4.0 total percent
delivery
defective
I
1/ Samples subjected to these tests shall not be delivered as part of the
contract or order but shall be discarded.
2/ The sample size shall be based only on the applicable sample size code
letter corresponding to the specified inspection level of MIL-STD-105.
k. 5
Inspection methods
4.5.1