4.5.2 Cleanliness examination. Each accessory set shall be examined
for cleanliness. The presence of any visible moisture, corrosion or
other contamination, metal chips, loose solder, burrs or sharp edges
shall cause the test set to be regarded as defective.
4.6 Tests.
Each accessory set shall be tested as follows:
NOTE : Test probes shall not be used to make electrical connections
to connectors. Jigs made up of mating connectors shall be used. Mating
connectors can be wired or their solder pots can be used as the test
points.
4.6.1 Electrical Continuity (M101). Measure the d-c resistance between
each directly connected pair of terminals as indicated in the following
tabulations. The tests shall be performed using an ohmmeter or bridge
having the minimum accuracy and range specified in 4.4.1. A measured
resistance exceeding 0.15 ohms shall constitute a defect.
Cable Assembly CA-55, Drawing 1260785:
Measure From
To
Plug S1, Contact
Plug Pl, Contact
v
1
T
1
P
2
s
7
R
8
Cable Assembly CA-57, Drawing 1260787:
To
Measure From
Plug S1, Contact
Plug Pl, Contact
1
v
1
T
5
P
s
6
R
8
Cable Assembly CA-58, Drawing 1260789:
Measure From
To
Plug S1, Contact
Plug Pl, Contact
v
1
T
1
P
2
7
s
R
8
|