MIL-A-23622
Level A - For level A packaging$ preservation shall be
5.1.1
in accordance with Specification MIL-P-116, Method II without preservative
compounds,
Level C - The actuators shall be preserved and packaged
5.1.2
individually in accordance with manufacturer's commercial practices,
Packing - Packing shall be in accordance with specifica-
5.2
tion MIL-P-7936, level A, B, or C as specified in contract or order. (see 6.2)
Marking - Interior and exterior containers shall be marked
5.3
in accordance with MIL-STD-129.
NOTES
6.
Intended use - The actuators covered by this specification
6.1.
are intended for use in aircraft control and actuator systems to actuate
landing gears, bomb-bay doors, wing flaps, trim tabs, Cowl flaps, duct doors,
selector valves and similar items.  One of these actuators may be used in
any application where its ability to meet the requirements is determined by
engi.neering -analysis.
.
Ordering data - Procurement documents should specify the
6.2
following:
(a) Title, number and date of this specification
(b) Number of actuators required
(c) Applicable MS and dash part number .
(d) Required level of packaging and packing (see 5.1)
(e) Installation instructions, handbooks, or manuals
when required,
6.3
Definitions -
Linear actuator - An item consisting of an electric motor
6.3.1
plus at least the following accessories:
(a) Limit switch(s), clutch, or other similar device
to control the amount of movement or force.
(b) A screwjack or similar device to convert the motor
torque to linear (straight line) motion.
Maximum operating load - The maximum operating load is
6.3.2,
the maximum or peak load which the actuator will ever be required to with-
stand during normal operation.
Ultimate load - Ultimate load is the load which the unit