MIL-A-48449A(AR)
With conditions of 3.6, the line of
3.9.4.1
Collimation.
sight  of  the  device  reticle  shall  be  parallel  in  elevation  with
the base of the dovetail within 0.1 mil and parallel in azimuth
within  0.1  mil  to  the  side  (angular  surface)  of  the  dovetail
(see  4.6.10).
When  the  alignment
3.9.4.2  Replacement  repeatability_.
device  is  removed  from  the  reference  dovetail  mount  and
remounted,  the  device  reticle  line  of  sight  shall
subsequently
meet  the  requirements  of  3.9.4.1  and  shall  not  have  changed
from  the  original  position  by  more than 0.1 mil (see 4.6.10).
3.9.5
Optical
characteristics.
Using  a  collimator  with  the  reticle
Parallax.
3.9.5.1
adjusted  to  be  parallax  free for a 80 meter target, the parallax
between  the  reticle  and  the  cross  on  the  alignment  device
reticle  shall  not  exceed  0.1  mil  (see  4.6.11).
Operability of moving parts.
3.9.6
The  alignment  device  shall  meet  all
3.9.6.1  Attachment.
functional  requirements  of  this  specification  when  the  alignment
device  mounting  bracket  or  a  suitable  substitute  is  employed
(see 4.6.10).
The latch shall be free to rotate to lock
3.9.6.2  Latch.
the  alignment  device  to  the  dovetail  on  the  alignment  device's
mounting  bracket  and  shall  be  free  to  rotate  to  release  the
This  requirement  shall  be  met  at
boresight  from  the  dovetail.
standard  ambient  conditions  and  at  the  temperatures  specified
in  3.8.2  (see  4.6.10).
Illumination.
3.9.7
The  reticle  marking  shall  be  clearly
Reticle.
3.9.7.1
distinguishable  when  observed  in  ambient  light  conditions
ranging  from  dusk  into  night  through  a  4-power  telescope  at  a
This  observation  must  be  made
distance of 10 feet
1 foot.
with and without the use of a 50% neutral density filter (see
4.6.12).
Any  part  of  tritium
3.9.8  External  tritium  contamination.
shall  not  be  present  on  the  external  surfaces  of  the  alignment
device  in  excess  of  1000  dpm/100  sq.  cm.  subsequent  to  the
requirements  of  3.8.1  through  3.8.4.2  (see  4.6.13).