MIL-A-48449A(AR)
Nomenclature
Description
1.
Temperature  Chamber;
Standard  type  conforming  to
Vibration  Equipment;  and
the  requirements  of  MIL-STD-
Shock
Equipment.
810  and  capable  of  providing
the  specified  test  conditions.
4.6
Test
methods
and procedures.
4.6.1
Orientation.
Test  fixture  conforming  to  Drawing
F9333945  will  be  used  for  the  inspection  of  the  Alignment
Device,  Optical,  Gun  Bore.
Affix-the  test  fixture  on  a  leveled,
vibration  free  surface  in  accordance  with  the  specified  set-up
The  calibration  and  set-up  instructions  are  the
instructions.
prime  requirements  necessary  to  establish  the  conditions  of  3.6,
prior  to  positioning  the  Alignment  Device  under  test  to  the  test
fixture.
The  Alignment  Device  under  test  shall  be  oriented  as
specified  in  3.6.
Operating  instructions  for  final  inspection
fixture  are  detailed  on  Drawing  F9333945.
4.6.2
Storage
temperature.
The  Alignment  Device  shall  be
exposed  to  each  temperature  extreme  specified  in  3.8.1  for  a
minimum  of  4  hours.
After  each  temperature  exposure,  the  align-
ment  device  shall  be  stabilized  at  standard  ambient  conditions
and  subjected  to  the  examinations  and  tests  to  determine
Caution  shall  be
conformance  with  the  requirements  of  3.8.1.
exercised  during  this  test  to  avoid  subjecting  the  alignment
device  to  thermal  shock.
The  Alignment  Device
4.6.3  Extreme  operating  temperature.
shall  be  exposed  to  each  temperature  extreme  specified  in  3.8.2
for a minimum of 4 hours.
After  exposure  for  4  hours  and  while
at  the  test  temperature,  operability  of  latch  shall  be  in  accor-
After-each  temperature  exposure,  the  Align-
dance  with  3.9.6.2.
ment  Device  shall  be  stabilized  at  standard  ambient  conditions
for  a  minimum  of  4  hours  and  subjected  to  the  examinations  and
tests  to  determine  conformance  with  the  requirements  of  3.8.2.
Caution  shall  be  exercised  during  this  test  to  avoid  subjecting
the  alignment  device  to  thermal  shock.
4.6.4  Shock.
The  alignment  device  in  its  carrying  case
or
equivalent  shall  be  tested  in  accordance  with  Method  516  of
MIL-STD-81O,  Procedure  I,  except  as  specified  in  3.8.3.
Subsequent  to  testing,  the  unit  shall  be  subjected  to  the
examinations  and  tests  to  determine  conformance  with  the
requirements  of  3.8.3.
11