| MIL-A-48449A(AR)
Contamination test
4.6.13
Radiological
contamination.
shall be performed by wiping the Alignment Device with filter
The wiping shall be
paper moistened in distilled water.
The damp filter paper
performed with moderate finger pressure.
shall be placed in a container with the proper portion of
The scintillating system used to measure
scintillation liquid.
The readout shall be within
contamination must be calibrated.
10% of the known standard value when counted to a total of 2000
The actual test for determining contamination
disintegrations.
is performed by placing the container into the scintillating
system.
The measured contamination shall be within the limits
specified in 3.9.8.
5.
PREPARATION
FOR
DELIVERY
Packaging and packing
5.1 packaging, packing, and marking.
shall be in accordance with Packaging Data Sheet 11741648.
Marking shall be in accordance with MIL-STD-129.
The level of
protection shall be as specified in the procurement document.
NOTES
6.
The alignment device is used to provide
6.1 Intended use.
an on-carriage optical reference to periodically check the
boresight setting of the fire control.
6.2 Ordering data .
Procurement
should
specify
the
following:
Title, number, and date of this specification.
a.
b.
Selection of applicable levels of preservation,
packing, and packaging.
c*
Applicable stock number.
d.
Provisions of First Article testing.
When a first article is required, it
6.3 First Article.
shall be tested and approved under the appropriate provisions
The
of 7-104.55 of the Armed Services Procurement Regulation.
first article sample shall consist of the first production
The contracting officer should
items and as specified in 4.2.
include specific instructions in all procurement instruments
regarding arrangements for examinations, test, and approval of
the first article.