| MIL-A-5034B
3.5
Adapter.
3.5.1 Construction. The construction of the adapter shall be
in accordance with the drawings listed in the data list for the adapter
being procured and as specified herein (see 6.2.lf).
3.5.2 Performance. The adapters shall satisfy all performance
requirements when subjected to the following inspections in the order
specifiec in Tables I and II.
a.
Adapter Inspection (see 4.6.1)
b.
Lag Time (see 4.6.2a)
c.
Vibration (see 4.6.2b)
d.
High-g Release (see 4.6.2c)
e.
Life (see 4.6.2d)
f.
Shock (see 4.6.2e)
Static (see 4.6.2f)
g.
h.
Salt Spray (see 4.6.2g)
3.6 Adapter hooks. The construction and inspection of the
adapter hooks shall be in accordance with MIL-H-85042.
3.7 Workmanship. The workmanship displayed in fabrication
and assembly of the adapter shall be such as to assure, within design
limitations, the ability of the adapter to meet performance requirements
under all applicable environmental conditions specified herein. Unauth-
orized repair, welding, heavy burrs, or parts assembled by introduction
of high stresses not prescribed in the drawings, are typical signs of
inferior workmanship and shall be cause for rejection. The standards of
workmanship exhibited in the approved first article sample, subject to
any qualification stated in the government's notice of approval, shall
be determinative of the requirements of the contract relative to work-
manship.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise speci-
fied in the contract, the contractor is responsible for the performance
of all inspection requirements as specified herein. Except as otherwise
specified in the contract, the contractor may use his own or any other
facilities suitable for the performance of the inspection requirements
specified herein unless disapproved by the government. The government
3
|