MIL-A-81371(AS)
(4) After each test is performed, all switches shall be placed in the
OFF positions prior to commencing of next test.
6.10.6
Logic-Level Reference - A voltage specified as a logical "O" shall not
exceed +0. S vdc, and a voltage specified as a logical "l" Shall be not less than +5 vdc nor
more than the positive supply voltage.
6.10.7
Individual Tests - The following tests shall be performed on each
assembly:
6.10.7.1
Diode Leakage Test - Connect 28V between pins "B" and "22" as shown
in figure 3. Current shall be less than 50 up.
6.10.7.2
Left Hand Stores Check (see figure 1)
6.10.7.2.1 Switch Transfer
(1) Switch S3 "O".
(2) Reset
(3) Pin 10 at a "1"
(4) switch S3 "OFF".
.
(5) Pin 10 at a "O".
(6)Switch S4 "On".
(7) Reset
(8) Pin 10 at a "l",
(9) Switch S4 "Off".
(10) Pin 10 at a "O".
6.10.7.2.2 One Count Transfer
(1) Reset
(2) Pin 10 at a "l".
(3) switch S1 "On".
(4) Pin 10 at a "l".
16