MIL-DTL-60426B (AR)
W/AMENDMENT 1
Conformance inspection by classification of characteristics
DRAWING NUMBER
PARAGRAPH
TITLE
9238842
4.3.2.4
Burster tube (prior to coating)
SHEET 1 OF 1
NEXT HIGHER ASSEMBLY
9238839
REQUIREMENT
CLASSIFICATION
EXAMINATION OR TEST
CONFORMANCE
INSPECTION METHOD
PARAGRAPH
CRITERIA
REFERENCE
Critical
None defined
Major
101
Total length, min.
Level IV
3.2
AIE
102
Diameter, min.
Level IV
3.2
AIE
103
Wall thickness
Level IV
3.2
AIE
Minor
204
Evidence of poor workmanship
Level II
3.7
Visual