| MIL-DTL-60426B (AR)
W/AMENDMENT 1
Conformance inspection by classification of characteristics
DRAWING NUMBER
PARAGRAPH
TITLE
9238839
4.3.2.6
Projectile burster M54A1 assembly
SHEET 1 OF 1
NEXT HIGHER ASSEMBLY
REQUIREMENT
CLASSIFICATION
EXAMINATION OR TEST
CONFORMANCE
INSPECTION METHOD
PARAGRAPH
CRITERIA
REFERENCE
Critical
*
1
Radiographic inspection
100%
3.6
4.4.1
2
Base plug missing
100%
3.2
Visual
3
Burster tube cracked
100%
3.2
Visual
4
Explosive charge loose in container
100%
3.2
Manual
5
Up arrow points in wrong direction
100%
3.2
Visual
6
Closure missing
100%
3.2
Visual
Major
101
Total length
Level IV
3.2
AIE
102
Chamber gage
Level IV
3.2
AIE
103
Explosive composition
4.4.2
3.5
4.4.2
Minor
201
Closing disc ruptured
Level II
3.2
Visual
202
Closing disc or base plug incompletely sealed
Level II
3.2
Visual
203
Ammunition lot numbering incorrect or illegible
Level II
3.2-3.3
Visual
204
Depth of explosive from top of tube
Level II
3.2
AIE
205
Evidence of poor workmanship
Level II
3.7
Visual
Visual
14
|