| MIL-DTL-60426B(AR)
W/AMENDMENT 1
b.
Packaging requirements. (See 5.1)
c.
Requirements for submission of first article sample.
d.
Certificate of Conformance for each lot or shipment of product.
e.
Provisions for Government furnished material.
f.
Requirements for submission of Contractor acceptance inspection equipment
designs. (See 6.4)
g.
Requirements for submission of zinc phosphate coating procedure. (See 6.5)
h.
Requirements for Certification of nondestructive test personnel. (See 6.6)
i.
Requirements for submission of radiographic procedure. (See 6.7)
j.
Requirements for submission of alternate explosive composition acceptance method
based on kettle composition. (See 6.9)
6.3 Ammunition lot numbering. Ammunition lot numbers to be assigned in accordance
with MIL-STD-1168.
6.4 Submission of contractor acceptance inspection equipment (AIE) designs for
approval. Submit copies of designs as required to: Commander U.S. Army ARDEC, ATTN:
AMSRD-AAR-QEM-A Picatinny, NJ 07806-5000 This address will be specified on the
Contract Data Requirements List, DD Form 1423 in the contract.
6.5 Zinc phosphate coating procedure. Unless otherwise specified by the procuring
agency, details of the proposed procedure including chemicals, equipment, and control tests to be
used by the contractor, are to be submitted in writing to the contracting office. Written approval
must be granted prior to the commencement of production. (See TT-C-490)
6.6 Certification of nondestructive test (NDT) personnel. All personnel operating or
calibrating NDT equipment to be qualified and certified in accordance with NAS-410.
Qualification to other standards must be submitted to and approved by Commander U.S. Army
ARDEC, ATTN: AMSRD-AAR-QEM-A Picatinny, NJ 07806-5000.
6.7 Radiographic procedures. Submit radiographic procedures, standards and sample
radiographs to: Commander U.S. Army ARDEC, ATTN: AMSRD-AAR-QEM-A Picatinny, NJ
07806-5000 for review and approval.
6.7.1 Radiographic film. Only a film type and vendor that has been approved by the
Government is to be used for radiographing this projectile. The final choice of film type must be
determined for the particular radiographic facility to be used and will be based on achieving
adequate sensitivity for both the IQI standard and inspected projectiles. A substitute item is not
to be used before prior testing and approval by the Government
6.7.2 Non-film methods of radiographic inspection. No non-film methods of
radiographic inspection should be employed without prior review and approval by ARDEC.
Qualification to be in accordance with ASTM E-1411 (Standard Practice for Qualification of
Radioscopic Systems) and an approved Qualification Plan. System performance and
implementation to comply with ASTM E-1255 (Standard Practice for Radioscopy).
Qualification must include a demonstration that the specific non-film system proposed for
20
|