| MIL-C-11015E
TABLE V. Group A inspection.
Examination or test
Requirement
Test
Sampling
paragraph
paragraph
procedure
Visual and mechanical examination
4.7.1
Materials
3.3
Body dimensions
3.1
See
Design construction
3.4
table VI
(other than body dimensions)
Marking 1/
3.20
Workmanship
3.23
Dielectric withstanding voltage
3.5
4.7.2
See
Insulation resistance
3.7
4.7.4
table VI
Capacitance
3.8
4.7.5
Dissipation factor
3.9
4.7.6
Solderability
3.16
4.7.13
13 samples
0 failures
1/ Marking defects shall be based on visual examination only. Any subsequent electrical
defects shall not be used as a basis for determining marking defects.
TABLE VI. Sampling plans for Group A tests.
Lot size
Sample size
1-
13
100%
14-
150
13
151-
280
20
281-
500
29
501-
1,200
34
1,201-
3,200
42
3,201-
10,000
50
10,001-
35,000
60
35,001-
150,000
74
150,001-
500,000
90
500,001-
Up
102
9
|