MIL-C-11015E
APPENDIX
40 EXTENT OF QUALIFICATION
40.1 Single-style submission. Capacitance-range qualification will be restricted to values equal to and less than
the capacitance value submitted. Capacitance-tolerance qualification will be restricted to tolerances equal to and
wider than the tolerance submitted. Voltage rating qualification will be restricted to that submitted. Rated
temperature and voltage-temperature-limit qualification will be restricted to that submitted. Qualification of one style
may be the basis for qualification of another style, as shown in table XII, provided that the dielectric material, rated
temperature and voltage-temperature limits, and dielectric thickness are essentially the same.
TABLE XII. Style qualification.
Style
May also qualify
CK13 - - - - - - - - - - - - - - -
CK12
CK14 - - - - - - - - - - - - - - -
CK13, CK12
CK15 - - - - - - - - - - - - - - -
CK14, CK13, CK12
CK16 - - - - - - - - - - - - - - -
CK15, CK14, CK13, CK12
CK61 - - - - - - - - - - - - - - -
CK60
CK62 - - - - - - - - - - - - - - -
CK61, CK60
CK63 - - - - - - - - - - - - - - -
CK62, CK61, CK60
CK65 - - - - - - - - - - - - - - -
CK64
CK66 - - - - - - - - - - - - - - -
CK65, CK64
CK67 - - - - - - - - - - - - - - -
CK66, CK65, CK64
CK69 - - - - - - - - - - - - - - -
CK68
40.2 Combined-voltage submission (styles CK60, CK63, and CK70). Capacitance-range qualification will be
restricted to values equal to and less than the capacitance value submitted. Capacitance-tolerance qualification will
be restricted to tolerances equal to and wider than the tolerance qualification will be restricted to tolerances equal to
and wider than the tolerance submitted. Voltage rating qualification will be restricted to those submitted. Rated
temperature (range) qualification will be restricted to ranges equal to and narrower than the widest range submitted.
Voltage-temperature-limit qualification will be restricted to limits equal to and wider than the narrowest limit
submitted.
40.3 Group submission. Qualification of type designation(s) within the group will be the basis for qualifying the
style(s) as shown in table XI.
Custodians:
Preparing activity:
Army - CR
DLA-CC
Navy - EC
Air Force - 11
DLA - CC
(Project 5910-2026)
Review activities:
Army AR, MI
Navy - AS, MC, OS, SH
Air Force - 19
20

Privacy Statement - Press Release - Copyright Information. - Contact Us