shall be based on no defects in the sample.  Further production of the
contractors by the supplier, prior to the approval of the preproduction
sample, shall be at the suppliers risk.
4.3.2 Lot size.  Unless otherwise specified in the contract or order,
each shipment of units of product shall be a separate "inspection lot"
and my differ from the quantity specified in the total order or contract.
In any event, all units of a single "inspection lot" shall be made to the
same design, with the same materials and manufacturing techniques, and
shall be part of one continuous production run.
4.3.3 Periodic production Samples. From each succeeding lot or grand
lot of 300 or less that have passed the quality conformance inspection of
4.4, a random sample of five series and five paralleling contactors will
be selected for submission to an activity designated by the procuring
activity to determine compliance of the samples with the requirements of
the contract, specification, and drawings. The contractors shall be con-
sidered satisfactory if they meet all specification and pertinent drawings
requirements and withstand the tests specified in 4.4 and 4.5. Failure
of the periodic production sample to comply with these requirements will
result in the rejection of the lot, as determined by the procuring activity.
4.4 Quality conformance inspection.  Each contactor delivered under con-
tract shall be subjected to the following tests and examinations. Failure.
to meet any requirement specified herein shall be considered cause for re-
jection.
4.4.1  Test conditions.  Unless otherwise specified, the contractors
shall be subjected to quality conformance tests under the following con-
ditions:
4.4.1.1 Temperature: Room ambient 65Fto95F (18C to 35C).
4.4.1.2 Altitude: Normal ground.
4.4.1.3 Vibration: None. .
4.4.1.4 Humidity: Room ambient to 95% relative, maximum.
4.4.2 Test and inspe ction equipment and facilities-  The manufacturer
shall furnish and maintain all necessary test equipment and facilities
"and shall provide personnel for performing all quality conformance tests.
The test equipment shall be adequate in quantity and, unless definite re-
quirements are specified, shall be of sufficient accuracy and quality to
permit performance of the required quality conformance tests.