3.6.3.2 With torque applied. When testted as specified 4.7.4.2, the locking
device shall not become disengaged.
3.6.4 Leakage, type I.
3.6.4.1 Coupling halves. The coupling leakage, when tested as specified in
4.7.5.1, shall not exceed 1 cubic centimeter (cc) per minute.
3.6.4.2 Coupling assembly. The coupling leafage, when tested as specified in
4.7.5.2, shall not exceed 1 cubic centimeter (cc) per minute.
3.6.4.3 Coupling assembly, with side load. The coupling leakage, when tested
as specified In 4.7.5.3 shall not exceed cubic centimeter (cc) per minute.
3.6.5 Pressure drop, type I. The pressure drop, when tested as specified in
4.7.6, shall be in accordance with Table I.
3.6.6 Proof pressure, type I. The coupling assemblies, when tested aS
specified in 4.7.7, shall not show any evidence of distortion, failure or
malfunction.
3.6.7 Operational test.
3.6.7.1 Type I. The coupling assembly leakage, when tested as specified in
4.7.8.1, shall not exceed 1.0 cc/min and the disconnecting and connecting torque
shall be as specified in 3.6.2.1.
3.6.7.2 Type II. The disconnecting and connecting torque, when tested as
specified in, shall be as specified in 3.6.2.2.
3.6.8 Burst pressure (static), type I. The coupling, when tested as
specified in 4.7.9, shall not rupture.
3.6.9 High temperature.
Type I.  The coupling assembly, when tested as specified in
3.6.9.1
4.7.10.1, shall not show any evidence of mechanical or material failure.
3.6.9.2 Type II.  The coupling assembly, when tested as specified in
4.7.10.2, shall not show any evidence of mechanical or material failure.
3.6.10 Vibration.
3.6.10.1 Type I.  The coupling assembly, when tested as specified in
4.7.11.1. shall not become disconnected during the test and shall not show any
evidence-of mechanical or material failure.
3.6.10.2 Type II. The coupling assembly, when tested as specified in
4.7.11.2, shall not become disconnected during the test and shall not show any
evidence of mechanical or material failure.
3.6.11 Salt fog.