| MIL-C-38418E(AS)
TABLE XIV.
Latitude Control (N) Resistance Settings
Latitude Control
Resistance
(Ohms)
(Degrees)
00.0
open
05.0
167,750
10.0
83,906
15.0
55,962
42,062
20.0
25.0
33,839
28,444
30.0
35.0
24,665
40.0
21,920
45.0
19,833
50.0
18,231
60.0
16,003
14,670
70.0
80.0
13,958
90.0
13,730
b.
Set the hemisphere selector switch to the S position and
change the connector 3J1-8 end of the adjustable resistance unit to
connector 3J1-9. Set the latitude control and ajustable resistance to
the values shown in table XV and read dc voltage from connector 3J1-S to
3J1-9. the voltage must not exceed 30 millivolts.
TABLE XV.
Latitude Control (S) Resistance Settings
Latitude Control
Resistance
(Ohms)
(Degrees)
00.0
open
28,444
30.0
90.0
13,730
Disconnect all test equipment.
c.
49
|