4.4.4.1 (Cont)
c. Electrical continuity.
d.
Missing or obstructed case vent.
e.
Missing or insufficient primer composition or propellant.
f.
Partially burned or contaminated primer composition or propellant.
The "Acc" number shall be 0 and the "Rej" 3 for misfire(s) associated with
a,b,c, or d. The second sample for evaluation of misfire(s) associated
with condition a, b, c, or d shall consist of the function and casualty
second sample (see Table I, Note 11/).  The lot shall be rejected if either
condition e or f is observed.  Misfire(s) occurring in the waterproofness
test shall be evaluated as specified in AMCR 715-505, Volume 8.
2/ Dwg. C7553663 (a detail of IEL 7259425) shall apply for classifying splits
and ruptures in fired cartridge cases. If a longitudinal spilt or circum-
ferential rupture (partial) extends into two or more defined areas, only
the most severe defect criterion of Table II for the areas involved, shall
apply. If a rupture results in separation of the cartridge case into two
or more portions, the defect shall be classed as a complete circumferential
rupture.
3/
Metal sheared or missing from the fired cartridge case exterior, such
as
a rim or neck shear, shall be classed as a defect. The lot shall not
be
penalized for metal shaved from the interior surface of the case neck
in
the crimped area.
4/ For classification as a defect, there must be evidence either by re-
covery of the band, or portion thereof, or by hole(s) in the fragmentation
screen(s).  The lot shall not be penalized for normal band fringing, or the
separation of a band fragment having no evidence of a band seat knurling
imprint, and having length of 0.5 inch or less.
5/ Separation or breakup of projectile part(s), except rotating band
separation, as witnessed by recovery of the part(s), of fragment(s), or
hole(s) in the fragmentation screen(s), shall be classed as a defect.
4.4.4.2 Unlisted Firing Defects. - The lot shall be suspended and referred
to the contracting officer for disposition, if a malfunction or casualty
not covered by this specification occurring in any firing test indicates
that the product is unsuited for the purpose intended.