| MIL-C-46941A
203
Heat sealer incomplete, loose, or distorted
Visual
204
Cut or damaged through impregnated box
Visual
205
Marking missing, incorrect, or illegible
Visual
4.6.8 Box, Ammunition, Packing, Drawing 8830981.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Strapping missing, loose, broken, or improperly assembled
Visual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of cartons incorrect
Visual
4.6.9 Box, Fiberboard (Outer), Alternative, Drawing 9225901.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.7 Test methods and procedures.
4.7.1 Primer x-ray. Prior to assembly into the cartridge, the primer shall be
radiographically examined in accordance with MIL-STD-453. Each primer shall be x-rayed on boards
or trays with the cup side perpendicular to the rays. The x-ray negatives shall be identified by
item nomenclature and by lot number. Primers are to be left mounted to the boards or trays until
after the x-rays have been reviewed and defects identified to facilitate removal of defective
units. After screening, the x-ray negatives with defectives identified, shall be forwarded to the
engineering activity designated by the acquiring activity. Interpretation of the radiographic
films shall verify the following:
11
|