| MIL-C-46941A
4.8.1 Reconditioning. The sample must be tested within ten minutes after removal from the
conditioning chamber. If this time is exceeded, the cartridge shall be reconditioned in
accordance with 4.8.
4.9 Inspection of packaging. The sampling and inspection of the preservation, packing, and
container marking shall be in accordance with the requirements of section 5.
5. PACKAGING
5.1 Packing and marking. Packing and marking shall be Level A or B, as specified by the
contracting activity (see 6.2). Level A shall be in accordance with Drawings 8830980 and 8830981.
Level B shall be in accordance with Drawings 8830980 and 9225901.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful but
is not mandatory.)
6.1 Intended use. The assembly is used in cartridge actuated devices for Aircrew Emergency
Escape Systems.
6.2 Acquisition requirements. Acquisition documents must specify the following:
a. Title, number, and revision letter of this specification
b. Issue of DODISS to be cited in the solicitation and, if required, the specific issue
of individual documents referenced and that MIL-STD-810D shall be used (see 2.1,
3.5.3, and 4.7.7)
c. Whether a first article sample is required (see 3.1, 4.4, and 6.3)
d. Test facility for first article tests (see 4.4.1)
e. Production test activity and lot size (see 4.1 and 4.5.1.2)
f.
Any special test conditions (see 4.3)
g. Directions for shipping radiographs of primers and of entire lot of cartridge
assemblies (see 4.7.1 and 4.7.4)
h.
Level of preservation and packing (see 5.1)
i.
That the safety precaution requirements of the ``Contractor's Safety Manual for
Ammunition, Explosives, and Related Dangerous Material,'' DOD 4145.26M are
applicable. NOTE: When this specification is used as part of the description of work