| ![]() MIL-C-48469B(AR)
TABLE V.
Test equipment.
4.6.2 Performance tests.
4.6.2.1 +13V output. Use items 1, 2 and 6 of table V or suitable
equipment to verify the requirements of 3.3.1.
4.6.2.2 115V, 400 Hz output. Use items 1, 2 and 6 of table V or suitable
equipment to verify the requirements of 3.3.2.
4.6.2.3 RP PWR FAIL output.- Use items 1, 2 and 6 of table V or suitable
equipment to verify the requirements of 3.3.3.
4.6.3 Environmental tests.
4.6.3.1 Shock.
4.6.3.1.1 Basic design. Use items 3, 4 and 5 of table V or mount the
assembly in a suitable shock fixture and subject the assembly to the shock
test specified in MIL-STD-810, method 516.2, procedure I, figure 516.2-2.
Apply three half sine wave shock pulses in each direction along the three
axes. Peak amplitude shall be 40 4 g with a time duration of 18 3 msec
measured at the 10 percent amplitude points. At the conclusion of this test,
subject the assembly to the performance tests of table II.
4.6.3.1.2 High intensity. Use items 3, 4 and 5 of table V or mount the
assembly in a suitable shock fixture and subject the assembly to the shock
test specified in MIL-STD-810, method 516.2, procedure IV, figure 516.2-2.
Apply three half sine wave shock pulses in each direction along the three
axes. Peak amplitude shall be 100.0 +10.0 g with a time duration of 1.5 0.2
msec measured at the 10 percent amplitude points. At the conclusion of this
test, subject the assembly to the performance tests of table II.