| MIL-C-50735(MU)
8 August 1973
3. 3.2 Environmental
3. 3.2.1 Storage temperature. The assembly shall meet the
requirements of 3.3.1 at ambient temperature after exposure to and
thermal stabilization at -80F and +160F.
3.3.2.2 Operating temperatures. The assembly shall meet the
requirements of 3.3.1 while exposed to and thermally stabilized at -40F
and +125F, subsequent to which the requirements of 3.3.1 shall be met
at ambient temperature .
3.3.2.3 Vibration. The assembly shall show no physical failure
and shall meet the requirements of 3.3.1 after being exposed to the
following vibratory conditions:
1 /64 inch, constant
a.
Amplitude:
(1/32 inch double amplitude)
b.
Vibratory
motion:
Simple harmonic
c. Sweep time:
5 to 55 to 5 Hertz in a five-
minute period
d. Vibration cycling:
Three linear or logarithmic
sweeps applied to each of the
three mutually perpendicular
axes.