MIL-C-50735(MU)
8 August 1973
4.6.5 Turn-on reset test. Turn off and then turn on the +1 5 Vdc
power at P1-5. Measure the time interval between the +15-volt power
turn-on and the change in level of the reset voltage at P1-21. Measure
the final voltage level at P1-21, verify compliance with 3.3.1.4.
4. 6.6 First-second-last logic and light drive test. Apply the
logical zero type-A signal of table I to the input terminals as specified
in table II. Measure the resulting output voltages for each input
condition to determine compliance with 3.3.1.5.
4.6.7 Malfunction logic and light drive test. Apply the logical
one and logical zero type-A signals of table I to the input terminals as
specified in table III. Measure the resulting output voltages for each
input condition to determine compliance with 3.3.1.6.
4.6.8 Blanking pulse test. With the togical zero type-A signal of
table I applied to P1-10, apply the type-A signal with the waveform shown
on figure 3 to P1-15. Observe the waveforms and amplitudes of the
outputs at P1-31 and P1-32 to determine compliance with 3.3.1.7.
4.6.9 Test switch test. Apply the logical one and logical zero
t y P e - A and the logical zero) type-B signals of table I to the input
terminals as spe~ified in table IV. Measure the resulting output
voltages for each input condition to determine compliance with 3.3.1.8.
4.6.10 Continuity test. With neither power nor signals applied,
measure the resistance between P1-33 and P1-34 to determine compliance
with 3.3.1.9.
4.6.11 Environmental tests
4.6.11.1 Temperature. The test apparatus shall be in accordance
with the applicable test facilities provision of MIL-F-13926 except that the
assembly may be mounted on the inside surface of the test chamber. Perform
this test in accordance with Procedure I of MIL-F-13926, with conditions
C (-40F) and E (+125F), and with the rate of temperature change during
cycling not greater than 8F per minute. At each of the specified operat-
ing temperatures, perform the tests of 4.6.2 through 4.6. 10 to determine
compliance with 3.3.2.1 and 3.3.2.2.