| ![]() MIL-C-50744A(AR)
3.4.2 Vibration. The assembly shall be capable of operating as specified
herein after exposure under the conditions of 3.1.3 to the vibration profile
of figure 6. Duration of exposure shall be not less than 80 minutes in each
of three mutually perpendicular axes. (See 4.6.3.2)
3.4.3 Operating temperature. The assembly shall be capable of operating as
specified herein over the operating temperature range of -40F to +160F.
(See 4.6.3.1)
3.4.4 Storage temperature. The assembly shall be capable of operating as
specified herein after exposure to storage temperatures ranging from -65F
to +160F. (See 4.6.3.1)
FIGURE 4. Reset signal waveforms.
(See 4.6.3.2)