| MIL-C-50744A(AR)
4.6.3.2.2 Vibration B. This test shall be conducted as in 4.6.3.2.1
except that the period of vibration shall be not less than 15 minutes in each
axis.
4.6.3.3 High temperature. Subject the assembly to the high temperature
test specified in MIL-STD-81O, method 501.1 procedure I. The highest
operating temperature shall be 140F. The performance tests of table V
shall be applied.
4.4.3.4 Low temperature. Subject the assembly to the low temperature
test specified in MIL-STD-81O, method 502.1, procedure 1. The storage
temperature shall be -65F. The lowest operating temperature shall be
-25F. The performance tests of table V shall be applied.
4.6.3.5 Temperature cycling. With power and loads of table I applied,
subject the assembly to the temperature profile specified in figure 7. At the
conclusion of this test$ subject the assembly to the performance tests of
table V.
22
|